Rosemount Pressure Transmitter

Product Overview

 

A Rosemount pressure transmitter measures process pressure and converts the measurement into an standardized output signal for process monitoring, control, and instrumentation systems.

 

  • Depending on the model, Rosemount transmitters can be configured for:
  • Differential pressure measurement
  • Gauge pressure measurement
  • Absolute pressure measurement
  • Differential-pressure-based flow measurement
  • Differential-pressure-based level measurement

The appropriate transmitter configuration depends on the required pressure range, measurement type, process medium, operating temperature, process connection, wetted materials, output signal, communication protocol, and installation arrangement.

 

 
First 1234 Last 1/4
 
Working Principle & Configuration
 

A pressure transmitter uses a sensing element to detect process pressure and converts the measured pressure into an electrical output. In a typical 4-20 mA HART configuration, the analog current represents the measured process variable while digital communication provides additional device information, configuration data, and diagnostic details.

Measurement Configurations & Typical Applications

Measurement Type

Typical Industrial Application

Gauge Pressure

Pipeline pressure, pump discharge, compressor pressure, vessel monitoring

Absolute Pressure

Vacuum systems and applications requiring absolute pressure reference

Differential Pressure

Flow measurement, filter monitoring, pressure-drop measurement, closed-tank level measurement

Remote Seal Configuration

High process temperature, corrosive media, viscous media, or difficult-to-access connections

Manifold Assembly

Isolation, equalization, and transmitter maintenance arrangements

In-Line Configuration

Direct process connection for applicable gauge or absolute pressure measurements

 

Rosemount 3051s Coplanar Pressure Transmitter

 

Key Features

Versatile Pressure References: Dedicated models and sensor ranges available for differential, gauge, and absolute pressure.


Multiple Output & Communication Options: Depending on the model, interfaces include 4-20 mA, HART, WirelessHART, FOUNDATION Fieldbus, and PROFIBUS.


Flexible Process Interfaces: Configurable with threaded/flanged connections, valve manifolds, and diaphragm seals.


Local Operator Interfaces: Optional local displays for on-site process indication and configuration.


Application Scalability: Factory or field-configurable for direct pressure, level, or DP-flow measurement systems.

 

Technical Specifications
 

Specifications vary by Rosemount model and ordering configuration. The following parameters should be verified during product selection and quotation:

Parameter

Selection Requirement / Verification

Product Type

Industrial Pressure Transmitter

Measurement Type

Differential, gauge, or absolute pressure

Pressure Range

Based on normal operating pressure and required span

Reference Accuracy

Model- and range-dependent

Rangedown & Static Pressure

Required for accurate DP and high-pressure applications

Wetted Materials

316L SST, Alloy C-276, Tantalum, etc. (match process medium)

Process Connection

Thread, flange, manifold, or seal arrangement

Output & Communication

4-20 mA HART, WirelessHART, Fieldbus, PROFIBUS

Power Supply & Electrical

Confirm cable entry and power requirements

Hazardous-Area Approvals

ATEX, IECEx, FM, CSA (confirm per installation location)

Accessories

Manifolds, remote seals, primary elements, process flanges

 

Applications
 

Pipeline & Process Monitoring

Gauge or absolute pressure tracking in pipelines, pump discharge lines, compressors, vessels, and utilities.

 

Differential Pressure & Flow Measurement

Filter and strainer differential pressure, equipment pressure drops, and DP flow measurement using primary elements (e.g., orifice plates).

 

Tank Level Measurement

Liquid level determination in closed, vented, or pressurized vessels using appropriate DP or gauge setups.

 

Chemical & Petrochemical Processing

Demanding environments requiring rigorous material compatibility, temperature ratings, and hazardous-area compliance.

 

Water & Utility Systems

Municipal water pipelines, pump stations, filter monitoring, and equipment protection.

 

OEM & Skid Systems

Engineered as core instrumentation for packaged skids, matching specific space, connection, and control architectures.

 

Supply Chain, Traceability & Quality Inspection

Procuring branded industrial instrumentation requires rigorous verification to ensure operational safety and project compliance:


Model & Ordering-Code Verification: Cross-check the requested model and ordering code against technical sheets or legacy equipment before order confirmation.


Configuration Audit: Validate measurement type, sensor range, output protocol, wetted materials, manifolds, and remote seals.

Nameplate Identification

For replacement orders, provide an existing nameplate photo or complete model code to guarantee an exact configuration match.

Documentation & Certification

Project-specific documents can include calibration certificates, certificates of conformity, material traceability (e.g., EN 10204 3.1), approval certificates, and inspection records. (Must be requested at quotation stage).

Supply Traceability

As a trusted supplier or channel partner, we provide clear product identification and reference official Emerson/Rosemount manufacturing specifications to ensure full transparency.

 

Product Selection & Configuration Workflow
 

To streamline your inquiry and ensure technical accuracy, follow this 7-step selection guide:

 

Step 1 - Define the Measurement Type: Specify differential, gauge, absolute, level, or flow.

 
 

Step 2 - Define the Pressure Range: Provide normal operating pressure, min/max limits, required span, and static pressure (for DP).

 
 

Step 3 - Check Process Conditions: Confirm medium, operating/ambient temperatures, corrosiveness, viscosity, solids, and vacuum conditions.

 
 

Step 4 - Select Process Connections & Wetted Materials: Match existing piping, flange standards, and corrosive-resistant alloy requirements.

 
 

Step 5 - Match the Control-System Interface: Confirm protocol compatibility (HART, Fieldbus, PROFIBUS) with your DCS, PLC, or SCADA host.

 
 

Step 6 - Confirm Approvals and Documentation: Specify hazardous-area ratings (ATEX/IECEx/FM), safety requirements, and calibration certificates.

 
 

Step 7 - Submit Complete RFQ Information: Send your parameters for a rapid, precise technical review.

 

 

FAQ

 

 

Q: What is a Rosemount Pressure Transmitter used for?

A: It measures differential, gauge, or absolute pressure, converting process variables into standardized signals for control systems. It can also be configured for advanced level and flow applications.

Q: How do I choose the correct Rosemount model?

A: Start with your measurement type, operating pressure range, process medium, temperature, connection style, and output protocol. For replacement projects, sharing the existing model code or a clear nameplate photo ensures a precise match.

Q: Can a Rosemount transmitter be supplied with a manifold or remote seal?

A: Yes. Applicable models can be factory-configured and assembled with valve manifolds, remote seals, and process flanges, ensuring safe installation for high-temperature, viscous, or corrosive media.

Q: Which output and communication protocols are available?

A: Depending on the model, options include 4-20 mA, HART, WirelessHART, FOUNDATION Fieldbus, and PROFIBUS, matching your plant's host control system.

Q: What documentation can be provided with the order?

A: Available documentation includes calibration certificates, certificates of conformity, material traceability, and hazardous-area approval records. These must be specified when requesting a quotation.

Q: What information should I provide for an accurate quotation?

A: Please provide:
Model or nameplate photo + measurement type + pressure range + static pressure + process medium + operating temperature + process connection + wetted material + output protocol + required approvals + manifold/remote seal requirements + quantity.

With abundant experience, we are one of the most professional rosemount pressure transmitter suppliers in China. Please feel free to buy high quality rosemount pressure transmitter in stock here and get quotation from our factory. Good service and low price are available.

Rosemount Differential Pressure Flow Meter, Flameproof Pressure Transmitter, Rosemount 2088 Gage and Absolute Pressure Transmitter