Yokogawa Pressure Transmitter

Product Overview

 

Industrial Pressure Transmitters are heavy-duty process instruments engineered for continuous, high-reliability measurement of differential, gauge, and absolute pressure across complex process automation systems.


At the core of this lineup is advanced proprietary single-crystal silicon resonant sensor technology. Unlike traditional capacitive sensors, this sensor directly outputs a digital frequency signal without intermediate analog-to-digital conversion, drastically minimizing thermal error and mechanical hysteresis.


Built to withstand harsh industrial environments--ranging from high-static-pressure natural gas pipelines to aggressive chemical reactors--these series provide dependable process data for control loops, safety instrumented systems, and custody transfer applications. Proper transmitter configuration depends strictly on the measurement type, operating pressure range, process temperature, static line pressure, process medium, wetted-part material, communication protocol, installation conditions, and required regional certifications.

 

 
First 12 Last 1/2
 
Measurement Principle & Configuration
 

Resonant Silicon Sensor

This technology utilizes a micro-machined single-crystal silicon resonant structure. Two H-shaped resonators are fabricated directly on the silicon chip. As process pressure is applied via isolating diaphragms and fill fluid, the resonant frequency of the active silicon beam shifts proportionally. An internal custom application-specific integrated circuit (ASIC) measures the frequency difference between the two resonators, translating physical pressure directly into a high-resolution digital signal. For applicable differential-pressure models, the sensor system simultaneously captures static pressure and sensor temperature data, which are used in real-time to cancel out common-mode line pressure and temperature-induced errors.

Typical Hardware Configuration

Depending on the selected model and factory options, a complete pressure transmitter assembly includes:
Sensor Module: Digital single-crystal silicon sensor with built-in compensation.
Electronics Housing: Dual-compartment, low-copper die-cast aluminum or stainless steel housing separating terminal wiring from electronic circuits.
Isolation System: Process isolating diaphragms and internal fill fluid.
Communication & Output: 4 to 20 mA DC with HART protocol, FOUNDATION Fieldbus, or PROFIBUS PA.
Local Interface: Optional integrated digital LCD indicator.
Mechanical & Safety Add-ons: Process flanges, mounting brackets, remote seal capillaries, and hazardous-area certification nameplates.

 

 
Key Features
 
01/

High Long-Term Stability: The single-crystal silicon structure ensures exceptional stability, significantly reducing recalibration drift in continuous-running plants.

02/

Active Temperature & Static Pressure Compensation: Real-time correction algorithms eliminate measurement errors caused by rapid process temperature swings and high line pressure.

03/

Robust Overpressure Protection: Engineered with internal dual-diaphragm structures to safely withstand high static overloads up to the maximum working pressure rating without permanent zero-point shift.

04/

Functional Safety Support: Designed to meet rigorous safety-related application standards and functional safety requirements.

05/

Modular Electronics: Interchangeable amplifier boards minimize spare parts inventory on-site.

06/

Flexible Communication: Multiple output options allow seamless integration into modern Distributed Control Systems and asset management software.

 

Technical Specifications

 

Technical Parameter

Specification / Selection Basis

Measurement Type

Differential Pressure (DP), Gauge Pressure (GP), Absolute Pressure (AP)

Sensor Technology

Resonant silicon sensing technology

Reference Accuracy

Model- and configuration-dependent (standard options vs. high-accuracy options)

Long-Term Stability

Model- and configuration-dependent under normal operating conditions

Working Pressure (Static)

Model-dependent (standard and high static pressure configurations available)

Process Temperature

Model-, fill-fluid-, seal-, and installation-dependent (standard up to 120 deg C; higher with remote seals)

Ambient Temperature

Model- and display-dependent (standard operational ranges apply)

Wetted Parts Materials

316L Stainless Steel, Hastelloy C-276, Tantalum, Monel process covers

Communication Output

4 to 20 mA DC with HART, FOUNDATION Fieldbus, or PROFIBUS PA

Enclosure & Protection

IP66 / IP67, Type 4X (NEMA 4X)

Hazardous-Area Approvals

Explosion-proof and intrinsically safe regional certification options

 

 
 
Applications

Oil & Gas Extraction & Refining

Wellhead pressure monitoring, distillation column differential pressure control, and custody transfer metering lines.

Chemical & Petrochemical Processing

Reactor vessel level monitoring under aggressive chemical exposure (utilizing specialized wetted parts) and high-temperature catalytic cracking units.

Power Generation

Boiler drum water level measurement, condenser vacuum monitoring, and turbine steam extraction pressure loops.

Water & Wastewater Treatment

High-accuracy aeration basin level control and high-pressure effluent line monitoring.

 

Eja530a Yokogawa Pressure Transmitter

Model & Configuration Selection (RFQ Checklist)

To ensure error-free engineering specification and prevent installation mismatches, please prepare the following parameters when requesting a quotation:


Select Measurement Type: Specify Differential Pressure (DP), Gauge Pressure (GP), Absolute Pressure (AP), or derived Level/Flow configurations.


Define Pressure Range: Provide minimum, normal, and maximum operating pressures, required measurement span, and maximum static pressure.


Determine Installation Requirements: Define process connections, mounting brackets, manifold requirements, remote seal capillaries, and local display options.

Define Pressure Range

Provide minimum, normal, and maximum operating pressures, required measurement span, and maximum static pressure.

Confirm Process Conditions

Note process medium name, normal/maximum operating temperatures, and corrosive characteristics.

Select Output & Communication

Specify control system interface protocols.

Specify Certification Needs

Outline required regional hazardous-area approvals and functional safety compliance.

 

Supply Chain, Quality & Global Support
 

To safeguard international projects against supply risks, technical and logistics teams enforce strict quality assurance procedures:

Authentic Sourcing & Traceability

All supplied transmitters originate from official authorized channels, complete with original factory serial numbers and traceable material test certificates.

Automated Calibration Rigs

Units undergo rigorous multi-point pressure testing across calibrated automated controllers with traceability to national metrology standards.

Secure International Export Packaging

Shipped in industrial-grade, moisture-barrier packaging with process connection caps secured to prevent thread damage or diaphragm puncture during transit.

Global Logistics Support

Backed by reliable international freight handling, secure air/sea export shipping, and comprehensive documentation packages (including Certificates of Conformance and factory calibration reports).

 

FAQ

 

 

Q: How do these transmitters handle static-pressure effects?

A: The dual-resonator design experiences identical frequency shifts when exposed to static line pressure. The internal digital algorithm evaluates the differential between the beams, effectively canceling out common-mode static pressure errors without manual zero adjustments.

Q: Which communication protocols are available?

A: Depending on the selected model code, available options include 4 to 20 mA with HART, FOUNDATION Fieldbus, and PROFIBUS PA.

Q: Can these transmitters be configured and calibrated remotely?

A: Yes. Transmitters equipped with digital communication protocols can be configured, zero-trimmed, and diagnosed remotely using handheld communicators, device management software, or distributed control system asset management tools through loop wiring.

Q: What hazardous area certifications are available?

A: Standard production models include multi-approval nameplates covering major international explosion-proof and intrinsically safe classifications.

Q: What information is required to generate an accurate quotation and model code?

A: Please provide your process variable, operating pressure range, maximum static pressure, process fluid/temperature, wetted material requirements, and hazardous area classification.

With abundant experience, we are one of the most professional yokogawa pressure transmitter suppliers in China. Please feel free to buy high quality yokogawa pressure transmitter in stock here and get quotation from our factory. Good service and low price are available.